Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Second Edition 2001.
(Current)
Short Description
Specifies requirements for the performance and construction of air filters for use in general ventilation and airconditioning systems. It classifies air filters on the basis of design, construction performance and application and establishes minimum criteria for acceptance of an air filter into a particular category. It does not apply to HEPA filters.

Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Third Edition 2012.
(Pending Revision)
Short Description
Sets out requirements for inspection, testing, preventive maintenance and survey of fire protection systems and equipment.

Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Second Edition 1999.
(Current)
Short Description
Specifies the classification of smoke-spill fans, and the laboratory test methods and procedures used to rate their performance (and that of their motors). Fans are rated in terms of their suitability to operate continuously without significant loss of performance, for a specified time at a specified air temperature. This Standard deals only with laboratory type-testing and does not consider the testing of smoke-spill fans after they have been installed in a building.

Type
Publisher
Standards Australia/Standards New Zealand
Publisher
Standards Australia/Standards New Zealand
Version:
Third Edition 2011.
(Pending Revision)
Short Description
Specifies minimum requirements for the operation and maintenance of air-handling and water systems of buildings for the purposes of microbial control. It does not include requirements for refrigerated room airconditioners and non-ducted split systems.

Type
Publisher
Standards Australia/Standards New Zealand
Publisher
Standards Australia/Standards New Zealand
Version:
Second Edition 2016.
(Current)
Short Description
Specifies a simple means of referring to common refrigerants instead of using the chemical name, formula, or trade name. It also establishes a uniform system to be used in assigning the proper reference number and classification to refrigerants; the system for refrigerant classification is defined and physical data of common refrigerants listed.

Type
Publisher
Standards Australia/Standards New Zealand
Publisher
Standards Australia/Standards New Zealand
Version:
Second Edition 2016.
(Current)
Short Description
Specifies requirements for safety and environmental aspects in relation to operation, maintenance and repair of refrigerating systems and the recovery, reuse and disposal of all types of refrigerant, refrigerant oil, heat transfer fluid, refrigerating system and part thereof.

Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Fifth Edition 2018.
(Pending Revision)
Short Description
The AS 3600 Concrete code; AS 3600 2009 specifies minimum requirements for the design and construction of concrete building structures and members that contain reinforcing steel or tendons, or both; sets out requirements for plain concrete and pedestal footings.

Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Third Edition 2024.
(Current)
Short Description
Provides designers of structures with earthquake actions and general detailing requirements for use in the design of structures subject to earthquakes with a primary focus on life safety.

Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Fifth Edition 2021.
(Current)
Short Description
Sets out procedures for the selection and installation of glass in buildings, subject to wind loading, human impact, and special applications. Glass strength is specified, based on the tensile stresses on the surface of the glass.

Type
Publisher
Standards Australia/Standards New Zealand
Publisher
Standards Australia/Standards New Zealand
Version:
Third Edition 2011.
(Pending Revision)
Short Description
Specifies minimum requirements for the design, installation and commissioning of air-handling and water systems of buildings for the purposes of microbial control. It does not include requirements for refrigerated room airconditioners and non-ducted split systems.